Disinfection & sterilisation of podology tools: a complete guide

28 July 2026 · 6 min read

Disinfection & sterilisation of podology tools: a complete guide

The three cleaning stages, correct solution concentrations and autoclave cycles for safe daily practice.

Why it matters Proper instrument reprocessing is the foundation of client and practitioner safety.

1. Pre-cleaning Immediately after use, immerse instruments in an enzymatic solution for 10-15 minutes so organic residue does not dry.

2. Disinfection Use a broad-spectrum solution at the concentration stated by the manufacturer. Rinse with deionised water and dry completely.

3. Sterilisation Pouch the instruments with an indicator and sterilise at 134°C for 4 minutes. Log every cycle.

Common mistakes - Overloading the autoclave - Storing on open trays - Skipping biological indicator checks